Output interface circuit examples, Analog inputs, Brake/drive enable application examples – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual
Page 74: Current draw for brake motor coils
Advertising
Publication 1398-5.2 – PDF 1997
6-10
Interfaces
Output Interface Circuit Examples
Analog Inputs
Two types of analog input circuits are available on the J1 connector:
Figure 6.10
BRAKE/DRIVE ENABLE Application Examples
Table 6.7:
Current Draw for Brake Motor Coils
MOTOR
24VDC
90VDC
MOTOR
24VDC
90VDC
F-4000
0.88A
0.26A
Y-1002
0.26A
NA
Y-1003
0.26A
NA
H-3000
0.60A
0.098A
Y-2006
0.31A
NA
H-4000
0.69A
0.17A
Y-2012
0.31A
NA
Y-3023
0.37A
NA
Suggested brake wiring when 24VDC brake current exceeds 500mA or for 90VDC brakes:
1398-DDM-005 and
1398-DDM-005X;
1398-DDM-009 and
1398-DDM-009X;
1398-DDM-019 and
1398-DDM-019X
1398-DDM-005 and
1398-DDM-005X;
1398-DDM-009 and
1398-DDM-009X;
1398-DDM-019 and
1398-DDM-019X