Fault Handling

Check the wire connection between all IDA8C/S on the Local Ateis Net.

If the wire connection is connected properly, the device must be checked as follow:

o

For IDA8C:

Prepare a working IDA8S, establish the Ateis Net wire connection between the IDA8C and
the IDA8S. Deploy the Ateis Net using Ateis Studio.

If the fault is not solved, please check the hardware version of Ateis Net card.

A quick examination for the Ateis Net card with RJ45 connectors (NOT the fiber

connectors), see the picture below.

hardw are V.105 or higher, w ith the resistors.

If your Ateis Net card doesn't have the resistors (as circled in the picture), it might cause
the connection problems. Please contact your Ateis dealer to replace it with a working one.

o

For each IDA8S on the Ateis Net:

Prepare a working IDA8C, establish the Ateis Net wire connection between the IDA8C and
the IDA8S. Deploy the Ateis Net using Ateis Studio and perform the examination as referred
to in the preceding paragraph.