4.1.11 Maintenance and Troubleshooting

This chapter will help you diagnose and troubleshoot common problems. The maintenance of the device
and peripherals are also explained in this section.

If none of these solutions work, please contact your Ateis dealer.

The LED indicators:

When the FAULT LED lights up

When the FAULT LED lights up, please check the

Log & Faults.

When the Network LED blinks

There are two situations that may cause the Network LED's to blink.

1. The Global Ateis Net ports are connected incorrectly. Please make sure they are connected

as A to B and B to A.

2. The firmware of the IDA8S needs to be updated. Please update the firmware to the most

recent version.

Can't search the devices in Ateis Studio:

We strongly recommend you perform the following steps after receiving the devices from the factory.

This will ensure that you connect the devices successfully.

The device does not have the TFT panel to see the IP address such as a UAP G2.