Parameter

Range

Comment

Reset

Button

Resets the echo cancellation on the channel

Far-End

Volume

Vu-meter

(dB)

Audio volume of the far-end audio signal.

Near-End

Volume (dB)

Vu-meter

(dB)

Audio volume of the near-end audio signal.

Near-End Level

-90 to 20 (dB)

Volume adjustment of the near-end audio signal

NLP

Selector:

Soft, Medium,

Aggressive, Off

NonLinear Process.

The purpose is to suppress the remaining echo

in a complex environment. It offers four functions:

Off: NLP function off

Soft: weak intensity of remain echo suppression.

Medium: medium intensity of remaining echo suppression.

Aggressive: aggressive intensity of remaining echo

suppression.

NLP Threshold

(dB)

-90 to 20 (dB)

The threshold value of the Nonlinear Process.

Noise

Reduction

Enable

Button

Enable the noise gate

NR Threshold

-90 to 20 (dB)

Threshold of the noise gate

6.1.2

Functions

The AEC component provides four fully independent channels.

On the component, each channel has one input called "far-in", and one output, and one reference called
"far-end". In order to send a proper signal to the other room, the far-end signal will be removed from the
far-in signal,