Mutes or unmutes the module's output.

Matrix Output Mute:

Mutes an input for the output mixing. Different than the Mute element, this element only affects
the output channel itself.

Matrix Output Level:

The attenuation of an input for the output mixing. Different than the Mute element, this element
only affects the output channel itself.

Output Level:

Sets the module's output level.

Threshold:

Sets the threshold for channel activation.

Background Threshold:

Sets how the input signal will be interpreted for opening a gate. The background level will
increase the input activation level.

Hold Time:

Sets the threshold for channel activation.

Attenuation Response Time:

Sets a pre-delay time for automatic attenuation. That means the transition time of the
attenuation when a channel is added or removed.

NOM Attenuation Step:

Sets the amount of attenuation applied each time the number of activated channels increases.

NOM Attenuation Max:

Limits the amount of attenuation applied.

Attenuation Gain:

Indicates the amount of current gain reduction.

Open Mic. Limits:

Chooses the maximum number of simultaneously activated channels.

NOM Attenuation Mode:

Choose this mode if you want a linear attenuation or a logarithmic attenuation be be more
realistic.

Eq1: (NOM-1) x step (same attenuation for each additional channel).

Eq2: log2(NOM) x step.