ATEIS - IDA8

486

© 2012 ATEÏS

Description:

This component controls the input signal's parameters and monitors it. The analog input modules
represent the physical analog inputs which are accessible on the rear panel of the Audio Processor.
There are several separate modules for use with each of the audio board slots. Analog input and
output modules are added automatically to the DSP window of the relevant processor by defining
their module configuration at the time you create them and should not be altered.

Control Window:

Element Properties:

Name

Initial

Minimum Maximum Precision

Unit

Bypass

Off

-

-

-

-

Mute

Off

-

-

-

-

Sensitivity

0dB

-

-

-

-

Phantom Power

Off

-

-

-

-

RTO

Off

-

-

-

-

Overload

Off

-

-

-

-

Volume

-50.0

-50.0

20.0

-

dB

Signal

Off

-

-

-

-

Level

0

-60.0

20.0

0.1

dB