Rear panel – ATEIS IDA8 User Manual

Page 172

Advertising
background image

ATEIS - IDA8

172

© 2012 ATEÏS

This LED light up if primary audio processor is active.

Primary Active Indicator:

This LED light up if secondary audio processor is active.

Fault Indicator:

This LED light up if the unit is set to be slave, and a short or open is detected on S. WD(Secondary
Watching Dog) port.

Note: If this indicator light up, it means there is an error of the unit, user needs to check wiring of S.
WD connector or replace by a good unit.

Power Indicator:

This LED light up if this unit is power on.

4.2.1.4.3 Rear Panel

PDC Audio Output for Record:

The audio output of peripheral plugged on PDC connector.

PDC Connectors:

There are 2 sets of PDC port in RU-Main, each set consist of three connectors, allow system to do
one PDC peripheral redundancy, the "N" is the number of set:

P_PDC N

Connect to one of primary audio processor's PDC connectors.

PDC N

Connect to peripheral which communicates to audio processor using PDC interface, for example
PSS AS, PPM AS.

S_PDC N

Connect to one of secondary audio processor's PDC connectors.

Advertising