Remote fault – ATEIS IDA8 User Manual

Page 117

Advertising
background image

Product Features

117

© 2012 ATEÏS

o

G. Fault LED on the front panel of the IDA8C/S.

Log:

Text messages display at the touch screen of the IDA8C:

"Remote Offline"

"PPM Port:2 ID:1", where Port N is the N

th

PDC port for the peripheral connection, the ID is

the unique number for each peripheral device on the PDC port.

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Replace the peripheral device with a working one. If the fault is resolved, the problem is from the
peripheral device. Send the peripheral device to your technician. If the fault is not resolved, change
the IDA8C/S and contact your technician.

4.1.7.1.16 Remote Fault

Fault Meaning:

An error is detected on peripheral devices. For PPM AS or PSS AS, this fault relates to a capsule
microphone or a speaker error.

Fault Indication:

LED Indicator

When this error is detected, the following LEDs will light up:

o

G. Fault LED on the front panel of the IDA8C/S.

Log

o

PPM AS / PSS AS Capsule Microphone Open:

Text messages display on the touch screen of IDA8C:

"Remote Fault"

"PSS Port:1 ID:1, Microphone Fault", where Port N is the N

th

PDC port for a peripheral

connection. The ID is the unique number for each peripheral device on the PDC port.

Text messages display at the window [Machine Fault Record] in Ateis Studio:

Advertising