To determine the boundary of the fault detection for a selected zone. There is a fault recognized
if one of the following conditions is true:

Measure < (Full Loaded Reference x (100% - Tolerance%))

Measure > (Unloaded Reference x (100% + Tolerance%))

Get Reference:

Get the reference values of the selected zone for further fault detection. Be aware, the hardware
configuration(IDA8C/S, amplifiers, wiring) should be completed before getting the reference.

Reset Reference:

Clear the reference values of the selected zone to initialize the status. If the reference value is
cleared, the monitoring will stop.

Measurement:

After the parameter settings are completed in the grid at the lower part, the IDA8C/S starts to
measure the value received from the internal circuit, and displays it on the grid at the upper part of
window:

Unloaded Reference:

Displays the value of an unloaded reference which is the gain of an amplifier when there is no
load to the zone. This value is used to determine if there is a fault of a normal amplifier.

Full Loaded Reference:

Displays the value of a full loaded reference which is the gain of an amplifier when there is a full
load to the zone. This value is used to determine if there is a fault of a normal amplifier.

Measure: