Logic Signal:

A paging request of the channel is established depending on the logic signal of an input.

Basically, if a logic is from Low to High and it will request a paging. On the other hand, if
from High to Low, it releases a paging request.

The settings allow you to put multiple channels to perform a logic operation AND/OR to
determine the paging activities.

o

Modulation + Logic Signal:

Under this mode, IDA8 decides to request a paging if both the modulation and logic signal
conditions are satisfied. It releases a paging request if one of the conditions is achieved.

o

Paging Event:

Binds a paging event for the zone selection. Only events with a singular type are selectable.
See the section "Zone and Priority" below for more details about the paging events.

Zone and Priority:

This section is about the zone section of a paging request, and to specify priority for judgment if
there are zones conflict with another paging source which occupies it.

There are two types of paging events:

o

Integration:

An integration paging event has multiple codes for zone selection. This is for each code
which is able to assign to the key of control consoles such as PPM AS and PSS AS.

By clicking the ellipsis button, a settings window of an integration paging event appears as
shown in the picture below: