Device

Connection Max. Num

Function

PPM AS

PDC

31

Remote console with paging ability.

PSS AS

PDC

1

Remote console for Paging and Event Triggering(Element

Control, Master/Sub Preset Control).

URC AS

PDC

1

Remote console for Master/Sub Preset Controlling and Element

Controlling.

URGP

PDC

1

Evacuation Input extension.

DNM

PDC

31

Auto noise gain for audio signals.

PPM-IT5

Ethernet

1 Active

Over Eth

Paging, Element Control and Master/Sub Preset Control.

URC200

TPC

Ethernet

Eth. Limit

Parameters Control and Master/Sub Preset Control.

CD8

PDC

31

Wall mounted cabinet remote paging console with 8 buttons/

zones.

CD16

PDC

31

Wall mounted cabinet remote paging console with 16 buttons/

zones.

CD Touch

PDC

1

Wall mounted cabinet remote paging console with touch screen

and Fireman Microphone.

PCP

PDC

31

Wall mounted cabinet remote paging console with telephone

styled microphone.

CDPM

PDC

31

Wall mounted cabinet remote paging console with 24 buttons/

zones and 2 extra selectable microphone sources.

PSC

PDC

31

A grouped console is comprised of a pad with a monitoring

speaker, a pad with a gooseneck and 8 buttons/zones, and two

pads with 8 buttons/zones.

Deskpad

PDC

1

A remote dialer for making telephone calls via IDA8's telephone

hardware.

Deskpad

Box

PDC

1

An RF transceiver to communication between Deskpad and

IDA8, use it, Deskpad can work without a physical connection.

Max. Num means you can connect one or more peripheral units through the connector by a using
Junction Box. For example: On the PDC, you can connect 32 PPM AS through junction boxes
and are able to assign IDs in sequence for each unit in Ateis Studio. Note: One IDA8C has 4 PDC
ports, and the sum of remote units is 32. Basically, fireman MIC already has one position
allocated, so this table only shows the maximum as 31.

Eth. Limit: The maximum number of IP that can be assigned over the network.

4.1.2.6

3rd Party Control

The following table lists 3rd Party Control protocols which are IDA8C Supported.

Protocol

Interface

Function

Connection

Settings

Ateis 3rd

Party

Protocol

Ethernet(UDP)

UDP Port =

19761

Read/Write value of parameters.
Stepped adjustment for parameters.

Modbus

PDC(RS485)

PDC Port 1~ 2

Level control
Paging
Read Monitoring Status
Read Evacuation Status
Play Message
Logic I/O Control