ATEIS IDA8 User Manual

Page 418

Advertising
background image

ATEIS - IDA8

418

© 2012 ATEÏS

Determines the maximum of automatic gain.

Limit the max gain to keep a natural audio dynamic.

Attack Time:

Adjusts the fade-in time to reach the target level.

A time that is too short will be uncomfortably heard with the audio peak when the speaker

begins to talk.

Release Time:

Adjusts the fade-out time of the signal when AGC is no longer working. This value is ignored if
the “Release button” is off.

A time that is too short will be uncomfortably heard with audio slack between the speaker's

words.

Sampling Time:

Average time needed by measuring the input level.

A time that is too long will make the AGC too insensitive on short peaks.

Level:

Level of the gain that AGC increased or decreased the input signal.

Example:

For example, we want to automatically adjust the gain of a type of vocal microphone.

On the "Input A" component, the input sensitivity is set to -40dB for standard dynamic microphone.

Advertising