Tone Settings

In the lower part of the window [Monitoring(Matrix Mode)-IDA8C/S X ], There is a page [Tone Settings] for
configuring the tone signal which is utilized for monitoring. There are two types of settings:

Zones with 0dB:

If the audio signal from Amplifier Zone Output is not returning to the IDA8C/S for monitoring, this
allows the user to mix a tone into that signal for further detection. You can change this setting in the
[Zone Settings] tab and the [Mode] field. There are parameters of settings:

Zone:

Indicates the zone number of parameters.

Mute:

Mutes the tone signal.

Level(dB):

The level of the tone signal.

Frequency(Hz):

The frequency of the tone signal.

Zones with 100V:

Frequency:

The frequency of the tone signal.

Enable 1K Tone: