Product Features

303

© 2012 ATEÏS

SPA 2240

The SPA were specifically developed to meet the requirements of EN 60849 for safety installations.
Each amplifier module is fitted with its own 220 VAC/24 VDC power supply for increased system
reliability. To avoid handling errors, the volume output is set using the potentiometer located at the back
of the apparatus. In addition to standard protection via fuses, SPA amplifiers also have electronic and
thermal protection to protect them from all potential hazards.

A fan provides forced cooling for the final power shelves and internal parts of the apparatus. It starts up
automatically when the temperature reaches a certain threshold, and stops when it returns to normal
values.

Four LEDs display the status of each amplifier: AC or DC power supply, Line Overload and Temperature
overload.

Furthermore, a three LEDs Vu-Meter indicates the presence and level of audio signal.

A surveillance circuit continuously monitors the temperature and the presence of AC and DC power
supplies for both amplifiers. In case of a problem, the overload LEDs will be switched ON and the Fault
relay will be activated.

The SPA series(SPA 2060, 2120, 2240) can be ordered with optional 115V power supply. Please
contact your local dealer or your regional ATEÏS branch office.

Specifications

Output power:

o

SPA 2060 : 2ch X 60W

o

SPA 2120 : 2ch X 120W

o

SPA 2240 : 2ch X 240W

Output voltage: 8 Ω, 70 & 100 V

Power type: 24 (range 21-28) VDC and 230 VAC

Connector (electronically balanced): 3-pin XLR and 3-pin phoenix

Frequency response: +/-3 dB @ 40 Hz and 20 kHz

S/N: >90 dBA

THD: < 1% @ 1 kHz

Input range: -6 dBV to 6 dBV / 770mV