Table of system faults, System fault list – ATEIS IDA8 User Manual

Page 88

Advertising
background image

ATEIS - IDA8

88

© 2012 ATEÏS

Name

Description

3. Line A/B short, a circuit outside the speaker zone output
connector is shorted, and no sound comes out. This fault may

damage the amplifier.

AMP Line Leakage Error

The current between the speakers and amplifiers has a leakage.

EVAC Input Error

The voltage of EVAC input is not in the range (when the evacuation

input is set to "contact mode").

AteisNet Broken

This fault happens when one or more IDA8C's or IDA8S's over Ateis

Net lose the connection.

Note: Global Ateis Net Broken only for global net IDA8.

Fireman Error

The fireman microphone has an error.

VOX@NET Error

The IDA8C/S can't communicate with the VOX@NET server.

Redundancy Error

1. It shows "Backup Device Offline" when a backup device can't

communicate.

2. It shows "Operation Mode Fail" for:

RU device is turned off.

The incorrect wiring between the RU and the IDA8.

Remote Offline

The peripheral devices (PSS AS/PPM AS/URC AS/...)

can't communicate with the IDA8C/S.

URGP Fault

The URGP device monitor is out of tolerance

Remote Fault

There is a hardware error of peripheral devices, such as the

microphone/speaker on a PSS.

File Corruption

The file CRC check code fails if the file monitor option is enabled.

ModBus Offline

The Modbus client can't communicate.

AMP Rating Fault

The IDA8 gets the reference value which is too low.

BackupAmp Used State

A normal amplifier fails and is replaced by the backup amplifier.

Local AteisNet Backup Mode

One of the local ATEIS net port has broken.

Global AteisNet Backup Mode

One of the global ATEIS net port has broken.

Note: Only for global net IDA8.

Bypass Mode

If using a redundancy unit, the IDA8 will enter the bypass mode

when a Bypass Mode fault occurs. If not, the IDA8 will enter in that

mode only when the "Bypass Input" line on the rear panel has

broken.

Major User Define Fault

The "Fault Define Security" component trigger.

Minor User Define Fault

The "Fault Define Security" component trigger.

Modan Offline

The Modan client can't communicate.

NTP Server Error

All the NTP server can't communicate.

Normal AMP Out of Toler.

The normal amplifier measure out of tolerance.

Backup AMP Out of Toler.

The backup amplifier measure out of tolerance.

4.1.7.1.1 Table of System Faults

Name

Description

Flash Error

An error occurred in the Nand flash inside IDA8C/S.

I2C Error

There is an internal error of I2C communication between micro

controllers.

Net Card Error

There is an error of communication between the main CPU in the

IDA8C/S and the Net card.

DSP Error

There is an internal error of communication between micro

controllers inside devices.

Preset Table Error

The structure of the configuration is not compatible with the current

firmware.