Remote offline – ATEIS IDA8 User Manual

Page 116

Advertising
background image

ATEIS - IDA8

116

© 2012 ATEÏS

"Backup Device Offline." or

"Operation Mode Fail."

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

The only power supply for RU is from IDA8s. In case the 24VDC output connector and wire are not
working right, the IDA8 can detect it and show the fault list on the touch screen as following:

VS_D12V_RL Error

-12V Error

12V Error

If anyone of them shows, please check the connections or replace the device.

Note: In case of a damaged relay of RU which cannot switch the system, the Primary IDA8 would
become the main system.

Once it's recovered, the LOG will show:

"RU OK: Backup Device Online."

"RU OK: Operation Mode Normal."

4.1.7.1.15 Remote Offline

Fault Meaning:

The IDA8C/S cannot communicate with peripheral devices.

Fault Indication:

LED Indicator:

When this error is detected, the following LEDs will light up: