Element Properties:

Name

Initial

Minimum

Maximum

Precision

Unit

Gate On

Off

-

-

-

-

Mute

Off

-

-

-

-

Bypass

Off

-

-

-

-

Thd.

-20.0

-90.0

35.0

0.1

dB

Hold Time

2000

10

5000

10

ms

Release Time

50

10

1000

10

ms

Voice

Recognition

Soft

-

-

-

-

Item list of Voice Recognition:

No.

Name

1

Soft

2

Medium

3

Accurate

Element Description:

Gate On

Lights up when the Gate-Voice is active (open).

Mute:

Mutes the Gate-Voice's module.

Bypass:

Switches off the Gate-Voice's operation.

Thd.:

The threshold to determine and pass the input signal.

Hold Time:

Time to close the output when no more human speech is detected.

Release Time:

Adjusts the fade-out time of the signal to decrease the signal after the hold time.