Product Features

37

© 2012 ATEÏS

Telephone Connector:

A connector for external telephone connection.(optional).

Bypass Mode Outputs:

This port is used to share the bypass mode microphone signals through the IDA8C-IDA8S network
(only needed when using fiber optic network).

Contact Outputs:

8 logic outputs channels are used to close/open a circuit for an external device. This contact is
normally open.

Evacuation Inputs:

9 evacuation contact inputs that allow the monitoring of external contact. They also can be used in
UGA mode, trigger by a voltage polarization change.

24V DC Output:

This connector supplies a 24VDC source.

24V DC Input:

Main 24VDC power supply connector.

AC Power Socket:

Main 110~240 V 1.2A, 47~63Hz AC power input with fuse. If 24V DC and AC power inputs are
connected at the same time, IDA8C will use AC power, and switch to DC power if there is no AC
power input.

Fuse Rating: 3.15A

Zone Boards

Zone Board1

The following I/Os belong to zone board1 in IDA8C: speaker zone output ch1~ch4, backup
amplifier1, amplifier zone output ch1 ~ ch4.

Zone Board2

The following I/Os are belong to zone board2 in IDA8C: speaker zone output ch5~ch8, backup
amplifier2, amplifier zone output ch5 ~ ch8.

4.1.1.4

Characteristics

Case:

Dimension = 436mm (W) x 313mm (L) x 88mm (H)

Weight = 5.36Kg

Color = RAL7016

Screen:

3.5" Color touch panel

Advertising