Element Properties:

Name

Initial

Minimum Maximum Precision

Unit

Overload

Off

-

-

-

-

Volume

-50.0

-50.0

20.0

0.1

dBu

Mute

Off

-

-

-

-

Signal

Off

-

-

-

-

Level

0

-60.0

20.0

0.1

dB

Overload thd.

3.0

-20.0

20.0

0.1

dB

Element Description:

Overload:

Indicates the channel level above the chosen Overload Threshold (dB).

Volume:

The Meter shows the channel level.

Mute:

Mutes or unmutes the output channel, the LED lights in red while the channel is muted.

Signal:

Indicates a channel is activated or not.