(Advanced) that is not allowed to mute or bypass the signal of the input. There are two ways to
adjust the delay time for a channel. The first is by adjusting element Delay time, the second is by
adjusting the Element Temp and Distance to compute the delay time. Element Type can be
switched between two modes.

Control Window:

Element Properties:

Name

Initial

Minimum

Maximum

Precision

Unit

Type

On

-

-

-

-

Delay time

0

0

*1

*2

µs

Temp

20

-10

50

0.1

°C

Distance

0

0

*3

0.01

m

*1: The maximum value of Delay time in various type of Delay (Basic).

Type

Maximum

5ms

5000 µs

50ms

50000 µs

100ms

100000 µs

200ms

200000 µs

500ms

500000 µs

1000ms

1000000 µs

2000ms

2000000 µs

*2: The precision value of Delay time in various type of Delay (Basic).

Type

Maximum

5ms

5 µs

50ms

20 µs

100ms

20 µs

200ms

20 µs

500ms

20 µs

Advertising