Control Window:

Element Properties:

Name

Initial

Minimum

Maximum

Precision

Unit

Mute

Off

-

-

-

-

Bypass

Off

-

-

-

-

Gate On

Off

-

-

-

-

Sidechain Gain

0

-35.0

35.0

0.1

dB

Input Gain

0

-35.0

35.0

0.1

dB

Thd.

-20

-90.0

35.0

0l.1

dB

Response Time

2

1

5000

1

ms

Attack Time

5

1

1000

1

ms

Hold Time

2000

1

5000

1

ms

Release Time

5

1

1000

1

ms

Depth

-50.0

-100.0

0

0.1

dB

Element Description:

Mute:

Mutes the Gate's module.

Bypass:

Switches off the Gate's operation.

Gate On:

Flashes when the Gate is active (open).

Sidechain Gain

Advertising