Redundancy error – ATEIS IDA8 User Manual

Page 115

Advertising
background image

Product Features

115

© 2012 ATEÏS

A buzzing sound output to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Observe the link and the active LED indicator on the RJ45 connector of the PC with the VOX@NET
server installed and ethernet switch. It is an error if the link LED is not lit up or active LEC is not
blinking. Possible causes are listed below:

Both the switch and PC receive an incorrect LED display behavior. Check the cable between
the PC & ethernet swich.

Only VOX@NET receive an LED display behavior. Check the network card of the PC. You can
change a network card to see if it is working properly.

Only switch can receive an LED display behavior. Check the switch, you can simply change
to another port to see if it is working properly.

Observe the link and active LED indicator on the RJ45 connector of the IDA8C/S and switch.
Possible causes are listed below:

Both the switch and IDA8C/S receive an incorrect LED display behavior. Check the cable
between the IDA8C/S & ethernet swich.

Only the IDA8C/S receive an incorrect LED display behavior. Check the IDA8C/S. You can
replace it with a working IDA8C/S to see if it is working properly.

Only the switch receive an incorrect LED display behavior. Check the switch. You can simply
change to another port to see if it is working properly.

4.1.7.1.14 Redundancy Error

Fault Meaning:

It shows "Backup Device Offline" when a backup device can't communicate.

It shows "Operation Mode Fail" for:

o

RU device is turned off.

o

The incorrect wiring between the RU and the IDA8.

Fault Indication:

LED Indicator:

When this error is detected, the following LEDs will light up:

o

G. Fault LED on the front panel of the IDA8C/S.

Log:

Text messages display at the touch screen of the IDA8C:

"Redundancy Error"