ATEIS IDA8 User Manual

Page 424

Advertising
background image

ATEIS - IDA8

424

© 2012 ATEÏS

6. Now look at the Over/Under red LED:

If both Over/Under LEDs are OFF, it means the calibration has properly finished and the A.N.
G. is ready.

If one of the Over/Under LEDs still lights up, it means the white noise level needed is out of
range.

7. Depending on the issue, a pop-up window will show you what to do. Follow the most useful advice

and restart the calibration process until the both Over/Under LED are OFF after the calibration.

8. The system is properly set.

Even when the paging is not active, the A.N.G. is still adjusting the AGC level with the ambient
noise to be ready for paging.

Notice:

The calibration should be done in normal ambient noise.

There should be no sudden loud

noise during the calibration.