No para. table, Ethernet broken – ATEIS IDA8 User Manual

Page 98

Advertising
background image

ATEIS - IDA8

98

© 2012 ATEÏS

Log:

Text messages display at the touch screen of the IDA8C:

"SSI error"

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Contact your technician to repair device.

4.1.7.1.3 No Para. Table.

Fault Meaning:

The IDA8 can't find the DSP parameters.

Fault Indication:

LED Indicator:

When this error is detected, the following LEDs will light up:

o

G. Fault LED on the front panel of the IDA8C/S.

Log:

Text messages display at the touch screen of the IDA8C:

"No Parameter Table"

Text messages display at the window [Machine Fault Record] in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Restore the parameters again.

4.1.7.1.4 Ethernet Broken

Fault Meaning:

The Ethernet connection fails. (If the ethernet monitoring has been enabled in ATEIS Studio)

Advertising