A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

1. Update the firmware with the newest version of Ateis Studio.

2. Store a configuration. If the problem is still not solved, please contact your technician.

4.1.7.1.1.6 No Preset Error

Fault Meaning:

There is no configuration inside the device.

Fault Indication:

LED Indicator:

When this error is detected, the following LEDs will light up:

o

System Fault LED on the front panel of the IDA8C/S.

o

G. Fault LED on the front panel of the IDA8C/S.

Log:

Text messages display on the touch screen of the IDA8C as:

"No Preset Table"

Also, the text messages display at the [Machine Fault Record] window in Ateis Studio:

A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.

Fault Handling:

Store a configuration to the device. If the error is still not solved, please contact your technician.

4.1.7.1.1.7 SPI Flash Error

Fault Meaning:

An internal error of micro controller SPI communication.

Fault Indication:

LED Indicator:

When this error is detected, the following LEDs will light up: