A zone assignment on the 9220 controller allows the recipe programs to change setpoints on all
slave instruments of a multi-zone furnace (up to 5 zones).

*Only used when running recipes
*Slave Instrument Setup must be configured prior to Zone Assignment setup
** Temperature zones link instruments to Temperature Setpoints

Assignments:
The zone assignment number, with a choice of Assignment 1 through Assignment 5.

Temp Instrument Number:
The slave instrument number assigned to a temperature controller, with a range of 0 to 25.

Temp Zone Number:

The zone within which the temperature setpoint change is desired, with a range of 0 to 5.

Default Zone Offset, temp:

This is the default zone offset for temperature, with a range of –32000 to 32000.

Furnace Setup

Configurator – Furnace Setup menu option


The Furnace Setup menu option is an administrative access only option. Do not make any
adjustments on the screen without first contacting Super Systems Inc..

PVT Type:
The PVT type is the mode the device runs in (Carbon, Dewpoint, etc.). The mode selected
determines the calculations and scaling for the Process Variable. Any time this selection is
changed it is necessary to reset the factory defaults to ensure all parameters have been
changed to the new Process Variable. Clicking on this value will display an input box with a