44

MEVT

OUT 2

Multiple event

output 2

Temperature

setpoint

Event mask (bit

map)

Event number OFF/ON

bit map

45 MEVT IN 0

Multiple event input

0

Temperature

setpoint

Event mask (bit

map)

Event number OFF/ON

bit map

46 MEVT IN 1

Multiple event input

1

Temperature

setpoint

Event mask (bit

map)

Event number OFF/ON

bit map

Identity Group

Value Opcode

Description

Temperature Atmosphere

Option

50

ID_SET

Set ID number

ID number value

N/A

N/A

51 ID_INC

Increment

ID

number

N/A

N/A

N/A

52

ID_INQ

ID number inquiry

ID number value

N/A

Equal,high, low

Temperature Group

Value Opcode

Description Temperature Atmosphere

Option

60 GRAMP

Guaranteed ramp

(temperature)

Temperature

setpoint N/A

Ramp time in

hours:minutes

61

PO_INQ

Test percent output

Temp PO

value (-200)

N/A

Wait, wait up, wait

down

62 QUENCH Start

quench

cycle

Quench

temperature

Quench time

(minutes)

Speed low, speed

high

63 RAMP Ramp

setpoints

Temperature

setpoint N/A

Ramp time in

hours:minutes

64

RAMPR

Ramp at rate

Temperature

setpoint N/A

Ramp time in

degrees per minute

65 SETPT

Setpoint

Temperature

setpoint

Loop or

instrument

None, wait, wait up,

wait down

66 TC_INQ

Temperature

inquiry

Temperature

level N/A

Wait, wait up, wait

down

67 ZONE_OFF

Set offset zone

Temperature

offset N/A

Zone number 0 to 4

(display 1 to 5)

68 QTCset

Quench temperature

setpoint

Temperature

setpoint N/A

N/A

69 SET_AUX

Set aux instrument

setpoint

Setpoint value

N/A

Instrument number

70 TZ_INQ

Temperature zone

inquiry

Temperature

level N/A

Wait, wait up, wait

down

71 GZRAMP

Guaranteed ramp

(TC zone)

Temperature

setpoint N/A

Ramp time in

hours:minutes

72 Z_SETPT

Setpoint, TC zone

Temperature

setpoint

Loop or

instrument

None, wait, wait up,

wait down

Time Group

Value Opcode

Description Temperature

Atmosphere

Option

80 SOAK

Soak

N/A

N/A

Soak time in

hours:minutes