Configurator – Furnace Setup menu option


The Furnace Setup menu option will allow the user to set up the furnace information.

Name:
This value will define the name of the furnace. Clicking on the “Value” column will bring up an
input box where the user can enter the furnace’s name.

Date and Time:
This value is the current date and time on the 9005 controller (not the local computer). Clicking
on the “Value” column will allow the user to set a new date and time on the controller.

Transfer Logic Enabled:
This value will determine if the transfer logic is enabled or disabled. The options are No or
Yes.

Temperature Mode:
This value will define the mode of the temperature (

°F or °C). The options are °F or °C.


Leak Up Event (0 disables):
This value will determine what the Leak Up Event will be. The range is 0 to 48, where 0 will
disable.

Leak Up Rate, max µ/hr:
This value will define the maximum leak up rate, in µ/hr. The range is 0 to 65.

Leak Up Retries, max:
This value will define the maximum leak up retries. The range is 0 to 500.

Leak Up Vacuum Gauge:
This value will define the leak up test gauge number. The range is 1 to 4.