20 snmp-server securityip – Accton Technology ES4626 User Manual

Page 83

Advertising
background image

83

{md5|sha} <password-string>}]

no snmp-server user <user-string> <group-string>

Function:

Add a new user to an SNMP group; the "no” form of this command deletes this

user

Command Mode:

Global Mode

Parameter: <user-string>

is the user name containing 1-32 characters

<group-string>

is the name of the group the user belongs to, containing 1-32 characters

encrypted

use DES for the packet encryption

auth

perform packet authentication

md5

packet authentication using HMAC MD5 algorithm

sha

packet authentication using HMAC SHA algorithm

<password-string>

user password,containing 1-32 character

Usage Guide:

If the encryption and authentication is not selected, the default settings

will be no encryption and no authentication. If the encryption is selected, the

authentication must be done. When deleting a user, if correct username and incorrect

group name is inputted, the user can still be deleted.

Example:

Add a new user tester in the UserGroup with an encryption safety level and

HMAC md5 for authentication, the password is hello.

Switch (Config)#snmp-server user tester UserGroup encrypted auth md5 hello

deletes an User

Switch (Config)#no snmp-server user tester UserGroup

2.4.3.20 snmp-server securityip

Command

snmp-server securityip {<ipv4-address>| <ipv6-address>}

no snmp-server securityip {<ipv4-address>| <ipv6-address>}

Function

Configure to permit to access security IPv4 or IPv6 address of the switch

NMS administration station; the “ no snmp-server securityip {<ipv4-address>|

<ipv6-address>}”command deletes configured security IPv4 or IPv6 address.

Command Mode

Global Mode

Parameter

<ipv4-address> is NMS security IPv4 address, point separated decimal

format

<ipv6-address> is NMS security IPv6 address, colon separated hex format.

Usage Guide

It is only the consistency between NMS administration station IPv4 or

IPv6 address and security IPv4 or IPv6 address configured by the command,

so it send SNMP package could be processed by switch, the command only

applies to SNMP.

Example

Configure security IP address of NMS administration station

Advertising
This manual is related to the following products: