Wiring of the standard device – Lenze EVS9332xK User Manual

Page 107

Advertising
background image

Wiring of the standard device

Standard devices in the power range 0.37 ... 11 kW

Motor connection

5

5.4

5.4.6

l

5.4−11

EDSVS9332K EN 8.0−07/2013

PE U

V

W

T1 T2

-UG +UG

PES

PES

PE

M

3~

PES

PES

KTY

X8/5

X7/9

X8/8

X7/8

PES

X8

X7

X9

X10

9300std073

Fig. 5.4−7

Circuit diagram for the motor connection with KTY temperature sensor at X7 or X8

Features of the connection for motor temperature monitoring:

Pins X7/8, X7/9 of resolver input (X7), or
pins X8/8, X8/5 of incremental encoder input (X8)

Connection

Linear KTY temperature sensor

Tripping point

l

Warning: adjustable

l

Error (TRIP): fixed at 150 °C

Notes

l

Monitoring is not active in the Lenze setting.

l

The KTY temperature sensor is monitored with regard to
interruption and short circuit.

Advertising
This manual is related to the following products: