Configuration, Code table – Lenze EVS9332xK User Manual

Page 294

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−20

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0464 CUSTOMER I/F

g 0

1

Original
Changed

Customer interface
Status of selected basic configuration

l

Reassignment of terminals in a basic
configuration of C0005 does not change
C0005 and sets C0464 = 1

l

Adding or removing function blocks or
changing the signal flow between the
function blocks in a basic configuration of
C0005 sets C0005 = 0 and C0464= 1

C0465

s

FB LIST

®

® Selection list 5 FB processing table

Contains the program for signal processing
(sequence in which the function blocks are
processed)

à

Depending on C0005. Changing C0005
loads the assigned processing table

à

Valid for C0005 = 1000

l

After changing the signal flow, the
processing table must be adapted.
Otherwise the controller may use the
wrong signals!

l

The function blocks DIGIN, DIGOUT,
AIF−IN, CAN−IN and MCTRL are always
processed and do not have to be entered
in the table.

1

200

2

0

3

50

4

0

5

0

6

55

7

0

8

0

9

10250

10

0

11

0

12

0

13

5650

14

0

15

0

16

5050

...

0

19

5700

...

0

22

10650

...

0

25

70

..

0

28

75

...

0

31

250

...

0

41

25000

42

20000

...

0

49

0

50

0

C0466 CPU T REMAIN

g

Remaining process time
Time remaining for processing function
blocks

C0469

s

FUNKTION KEY
STOP

2

0
1
2

Switched off
Set controller inhibit
Set quick stop

Setting the function of the keypad STOP key

Advertising