Internal voltage supply

ƒ For the supply of the digital inputs (X5/E1 ... X5/E5) you have to set a

freely assignable digital output (e. g. X5/A1) permanently to HIGH
level.

ƒ For the supply of the analog inputs (X6/1, X6/2 and X6/3, X6/4) you

have to set a freely assignable analog output (e. g. X6/63) permanently
to HIGH level.

GND2

+24V

E5

A2 A3 A4 ST1ST2 59

39

3k

47k

50mA

50mA

50mA

50mA

X5

28 E1 E2 E3 E4

3k

3k

3k

3k

3k

S1

A1

X3

X6

1

2

3

4

242R

1
2
3
4
5
6

100k

100k

100k

100k

3.3nF

GND1

GND1

7

7

62 63

AIN1

AIN2

AOUTx

AOUT2

AOUT1

1

3

2

4

7

10k

10k

9300vec201

Fig. 5.8−3

Wiring of digital and analog inputs/outputs for internal voltage source

S1

Controller enable
NO contact or NC contact

Z

Load
Minimum wiring required for operation

Terminal assignment in the Lenze setting:

^ 5.8−9

Supply via external voltage source

GND2

+24V

E5

A2 A3 A4 ST1ST2 59

39

3

k

47

k

50

mA

50

mA

50

mA

50

mA

X5

28 E1 E2 E3 E4

3

k

3

k

3

k

3

k

3

k

DC 24 V
(+18 V … +30 V)

S1

+

A1

X3

GND1

GND1

X6

1

2

3

4

7

7

62 63

242R

1
2
3
4
5
6

100

k

100

k

100

k

100

k

3.3nF

AIN1

AIN2

AOUTx

AOUT2

AOUT1

1

3

2

4

7

10k

10k

9300std077

Fig. 5.8−4

Wiring of digital and analog inputs/outputs for external voltage source

S1

Controller enable
NO contact or NC contact

Z

Load
Minimum wiring required for operation

Terminal assignment in the Lenze setting: