Troubleshooting and fault elimination

Error messages during profile download

9

9.4

l

9.4−4

EDSVS9332K EN 8.0−07/2013

Remedy

Cause

Fault name

Code

C0505/4

Pointer on Y values, selection of an interpolation point on the Y axis

INV_LENGTH_RANGE The selected interpolation

point does not exist.

Observe the existing number of interpolation points under
C0391/x.

C0511/1

Write X values in physical units [m_units] with automatic indexing of the address pointer (auto−increment)

INV_LENGTH_RANGE Attempt to write beyond the

data field.

l

Limit the number of writing cycles to the existing number of
interpolation points (see C0391/x).

l

Set the pointer to the beginning of the value table
(C0505/3 = 0).

INV_COLLISION_
RANGE

Relative data model is used
(Lenze setting). The address
pointer has not been
incremented.

Use GDC to create a profile with the absolute data model, load
it into the controller and accept it.

INV_VALUE_RANGE

Attempt to transfer a
non−zero value as the first X
value

Enter 0" for the first X value.

C0511/2

Read X values in physical units [m_units] with automatic indexing of the address pointer (auto−increment)

INV_LENGTH_RANGE Attempt to read beyond the

data field.

l

Limit the number of reading cycles to the existing number of
interpolation points (see C0391/x)

l

Set the pointer to the beginning of the value table
(C0505/5 = 0).

C0512/1

Write Y values in physical units [s_units] with automatic indexing of the address pointer (auto−increment)

INV_LENGTH_RANGE Attempt to write beyond the

data field.

l

Limit the number of writing cycles to the existing number of
interpolation points (see C0391/x).

l

Set the pointer to the beginning of the value table
(C0505/4 = 0).

INV_VALUE_RANGE

The relative data model is
selected.
While writing the Y value,
the representable value
range has been exceeded .

l

Observe the maximum permissible difference between Y
values of

32767 inc.

l

This profile requires a larger number of interpolation points.

l

Increase the number of interpolation points (via GDC) and
completely repeat the transfer of the profile.

C0512/2

Read Y values in physical units [m_units] with automatic indexing of the address pointer (auto−increment)

INV_LENGTH_RANGE Attempt to read beyond the

data field.

l

Limit the number of reading cycles to the existing number of
interpolation points (see C0391/x).

l

Set the pointer to the beginning of the value table
(C0505/6 = 0).