Configuration, Code table – Lenze EVS9332xK User Manual

Page 286

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−12

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0183 DIAGNOSTICS

g

Drive diagnostics

l

Indicates fault or status information

l

If several fault or status information units
are active simultaneously, the information
unit with the smallest number is displayed

0

OK

No fault

91

TRIP set C0135

TRIP via LECOM−A/B/LI or keypad

92

Trip−Set AIF

TRIP via AIF

93

Trip set CAN

TRIP via CAN

101

Initialisation

Initialisation phase

102

TRIP/fault

TRIP active

103

Emergency stop

Emergency stop has been executed

104

Pulse inhibit message

Message active

105

Power OFF

Function is not supported

111

Operation inhibit−C135

Operation inhibited

112

Operation inhibit−AIF

113

Operation inhibit−CAN

121

Controller inhibit, terminal 28

Controller inhibited via X5/28

122

Controller inhibit, internal 1

DCTRL−CINH1

123

Controller inhibit, internal 2

DCTRL−CINH2

124

Controller inhibit−C135/STOP

STOP key at the keypad

125

Controller inhibit−AIF

Controller inhibited via AIF

126

Controller inhibit−CAN

Controller inhibited via system bus

141

Switch−on inhibit

Restart protection active

142

Pulse inhibit

High−resistance power outputs

151

QSP−terminal, external quick stop

Quick stop via MCTRL−QSP

152

QSP−C135 quick stop

Quick stop via STOP key of the keypad

153

QSP−AIF quick stop

Quick stop via AIF

154

QSP−CAN quick stop

Quick stop via system bus

250

Warning C168

Warning active

C0190 NSET ARIT

0

0
1
2
3
4
5

OUT = C46
C46 + C49
C46 − C49
C46 * C49
C46 / C49
C46/(100 − C49)

NSET
Arithmetic block in the function block NSET
Connects main setpoint C0046 and additional
setpoint C0040

C0195 BRK1 T ACT

99.9

0.0

{0.1 s}

99.9 BRK1 brake engagement time

Engagement time of the mechanical holding
brake

l

After the time under C0195 has elapsed,
the status "mechanical brake closed" is
reached

C0196 BRK T RELEASE

0.0

0.0

{0.1 s}

60.0 BRK1 brake disengagement time

Disengagement time of the mechanical
holding brake (see technical data of the
brake).

l

After the time under C0196 has elapsed,
the status "mechanical brake open" is
reached

C0200 S/W ID

g

Software ID
Software identification

C0201 S/W DATE

g

Software release
Date of software release