Commissioning

Commissioning examples
Multi−axis application

6

6.14
6.14.2

l

6.14−6

EDSVS9332K EN 8.0−07/2013

The following settings have to be carried out for all slaves.

9300std227

Fig. 6.14−6

"CAN−Slave" menu of the parameter menu

Procedure

1.

Change to the "CAN−Slave" menu.

2.

Set C0353/2 = 1 (extra address C354).

l

This setting "links" the slaves to the address of the master.

3.

Enter the value from C0354/4 (CAN master) under C0354/3.

4.

Set C0366 = 0 (no sync response). This reduces the load on the bus.

5.

Set C0369 = 0.

l

This setting prevents the slave drives from sending sync telegrams.

6.

Set C1120 = 1 (CAN sync activated). This setting activates the sync telegram
synchronisation.

7.

Set the time interval at which the slave is to receive the sync telegrams from the master
under C1121.

l

The time interval must be identical to the time interval set under C0369 ( CAN Sync Tx
time" of the master).

l

See section "Master settings": 5 ms

8.

Set C1332 = 1. The master value is provided by CDATA−XIN.

9.

If possible, locate the function block SYNC2 at the beginning of the processing table.

10. Link the output CAN−IN2.D1 to the input CDATA−XIN.

11. If you do not use the function block CAN−OUTx, check that the CAN−OUT address used is

not identical to the one used by the master.

l

The function blocks CAN−INx are entered in the processing table by default.

12. Save the settings with C0003 = 1.

Settings for CAN slave