Configuration – Lenze EVS9332xK User Manual

Page 322

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−48

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1072

s

® Selection list 3 RFGPH2, RFGPH3

Configuration of input signals

1 CFG:

RFGPH2−SET

1000 FIXED0INC

2 CFG:

RFGPH2−ACT

1000 FIXED0INC

3 CFG:

RFGPH3−SET

1000 FIXED0INC

4 CFG:

RFGPH3−ACT

1000 FIXED0INC

C1073

g

RFGPH2, RFGPH3
Display of input signals

1 (C1072/1)

... ...

4 (C1072/4)

C1074

0
1
2

RFGPHx−PHOUT = 0
RFGPHx−PHOUT = ACT
RFGPHx−PHOUT = SET

RFGPH2, RFGPH3
Mode for reset

1

0

RFGPH2−PHOUT

2

0

RFGPH3−PHOUT

C1075

RFGPH2
Mode

0

Without limit stop

The output signal at RFGPH2−PHOUT
continuously follows the setpoint at
RFGPH2−SET

1

With limit stop

The output signal at RFGPH2−PHOUT follows
the setpoint at RFGPH2−SET for the length of
a positioning process.
After a HIGH−LOW edge at RFGPH2−STOP, the
output signal continues to follow the
setpoint again.

C1076

RFGPH3
Mode

0

Without limit stop

The output signal at RFGPH3−PHOUT
continuously follows the setpoint at
RFGPH3−SET

1

With limit stop

The output signal at RFGPH3−PHOUT follows
the setpoint at RFGPH3−SET for the length of
a positioning process.
After a HIGH−LOW edge at RFGPH3−STOP, the
output signal continues to follow the
setpoint again.

C1077

0

{1 inc}

32767 RFGPH2, RFGPH3

1

5

RFGPH2: Catch

2

5

RFGPH3: Catch

C1078

0

{0.0001

rpm}

14000.0000 RFGPH2, RFGPH3

1

200.0

000

RFGPH2: N

max.

forward

2

200.0

000

RFGPH2: N

max.

return

3

200.0

000

RFGPH3: N

max.

forward

4

200.0

000

RFGPH3: N

max.

return

Advertising