Configuration, Code table – Lenze EVS9332xK User Manual

Page 278

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−4

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0027

−199.99

{0.01 %}

199.99 FCODE (gain AIN)

Freely assignable code for relative analog
signals

l

Used for:
– Gain X6/1,2
– Gain X6/3,4

1 FCODE (GAIN)

100.0

0

2 FCODE (GAIN)

100.0

0

C0030 DFOUT CONST

3

0
1
2
3
4
5
6

256 inc./rev.
512 inc./rev.
1024 inc./rev.
2048 inc./rev.
4096 inc./rev.
8192 inc./rev.
16384 inc./rev.

DFOUT constant
Constant for the digital frequency output in
increments per revolution

C0032 FCODE

GEARBOX

1

−32767

{1}

32767 FCODE (gearbox factor numerator)

Freely assignable code

C0033 GEARBOX

DENOM

1

1

{1}

32767 Gearbox factor denominator

C0034 MST CURRENT

0

0
1
2

−10 V ... + 10 V
+4 mA ... +20 mA
−20 mA ... +20 mA

Master voltage/master current
Selection for setpoint entry

C0037 SET−VALUE

RPM

0

−16000

{1 rpm}

16000 Setpoint selection (rpm)

C0039

−199.99

{0.01 %}

199.99 NSET JOG setpoints

Fixed speeds (JOG setpoints) can be selected
for NSET using digital inputs

1 JOG SET−VALUE 100.0

0

2 JOG SET−VALUE 75.00

3 JOG SET−VALUE 50.00

4 JOG SET−VALUE 25.00

5 JOG SET−VALUE

0.00

... ...

...

14 JOG SET−VALUE

0.00

15 JOG SET−VALUE

0.00

C0040 CTRL ENABLE

1

0
1

Controller inhibited
Controller enabled

Controller enable (RFR)

C0042 QSP

g 1

2

QSP: Inactive
QSP: Active

Quick stop

C0043 TRIP RESET

0

0
1

Trip reset
Error active

Reset error
Reset of an active trip:

l

Set C0043 = 0

C0045 ACT JOG

g 0

1
2
...
15

Nset is active
JOG 1
JOG 2
...
JOG 15

NSET
JOG selection

C0046 NSET−N

g −199.99

{0.01 %}

199.99 NSET

Main setpoint

C0049 NSET−NADD

g −199.99

{0.01 %}

199.99 NSET

Additional setpoint

C0050 MCTRL−NSET2

g −100.00

{0.01 %}

100.00 MCTRL

n

set

at speed controller input

C0051 MCTRL−NACT

g −30000

{1 rpm}

30000 Actual speed value

C0052 MCTRL−UMOT

g 0

{1 V}

800 Motor voltage

C0053 UG−VOLTAGE

g 0

{1 V}

900 DC−bus voltage

Advertising