Configuration, Code table – Lenze EVS9332xK User Manual

Page 300

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−26

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0582 MONIT OH4

2

2
3

Warning
Off

OH4 monitoring
Configuration of heatsink temperature
monitoring

C0583 MONIT OH3

®

0
2
3

Trip
Warning
Off

OH3 monitoring
Configuration of monitoring for "fixed motor
temperature"

à

Depending on C0086

C0584 MONIT OH7

®

2
3

Warning
Off

OH7 monitoring
Configuration of monitoring for "adjustable
motor temperature"

à

Depending on C0086

Temperature monitoring via resolver input

C0585 MONIT OH8

3

0
2
3

Trip
Warning
Off

OH8 monitoring
Configuration of monitoring for "adjustable
motor temperature"
Temperature monitoring via PTC input

C0586 MONIT SD2

0

0
2
3

Trip
Warning
Off

SD2 monitoring
Configuration of resolver monitoring

C0587 MONIT SD3

3

0
2
3

Trip
Warning
Off

SD3 monitoring
Configuration of monitoring for "encoder at
X9"

C0588 MONIT

H10/H11

0

0

Trip

H10 / H11 monitoring

2
3

Warning
Off

Only Lenze service personnel is permitted to
set C0588 = 2 or C0588 = 3

C0589 MONIT P03

2

0
2
3

Trip
Warning
Off

P03 monitoring
Configuration of following error monitoring

l

Function block DFSET monitors the
following error. Monitoring is only active if
DFSET is used.

C0590 MONIT P13

0

0
2
3

Trip
Warning
Off

P13 monitoring
Configuration of phase error monitoring

l

Function block DFSET monitors the
following error. Monitoring is only active if
DFSET is used.

C0591 MONIT CE1

3

0
2
3

Trip
Warning
Off

CE1 monitoring
Configuration of "CAN−IN1 error" monitoring

C0592 MONIT CE2

3

0
2
3

Trip
Warning
Off

CE2 monitoring
Configuration of "CAN−IN2 error" monitoring

C0593 MONIT CE3

3

0
2
3

Trip
Warning
Off

CE3 monitoring
Configuration of "CAN−IN3 error" monitoring

C0594 MONIT SD6

®

0
2
3

Trip
Warning
Off

SD6 monitoring
Configuration of "motor temperature sensor"
monitoring

à

Depending on C0086

C0595 MONIT CE4

3

0
2
3

Trip
Warning
Off

CE4 monitoring
Configuration of "CAN bus off" monitoring

C0596 NMAX LIMIT

5500 0

{1 rpm}

16000 System speed monitoring

C0597 MONIT LP1

3

0
2
3

Trip
Warning
Off

LP1 monitoring
Configuration of motor phase failure
monitoring

C0598 MONIT SD5

3

0
2
3

Trip
Warning
Off

SD5 monitoring
Configuration of monitoring for master
current at X5/1.2 < 2 mA

Advertising