Standard devices in the power range 0.37 ... 11 kW
Motor connection

5

5.4
5.4.6

l

5.4−12

EDSVS9332K EN 8.0−07/2013

PE

U V W

T1T2

U, V, W
T1, T2

0.5...0.6 Nm
4.4...5.3 lb-in

2

1

0

9300vec122

Fig. 5.4−8

Motor connection with KTY thermal sensor

0 Motor cable

1 Shield sheet

Clamp the motor cable shield with the straps. If required, fix by means of
cable tie.

2 U, V, W

Motor cable connection
Check the correct polarity. Observe maximum length of the motor cable. Use
wire end ferrules for flexible cables.
Max. connectable cable cross−section: 4 mm

2

, with pin−end connector

> 4 mm

2