Configuration, Code table – Lenze EVS9332xK User Manual

Page 282

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−8

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0108

100.0

0

−199.99

{0.01 %}

199.99 FCOD (gain AOUT)

1 FCOD

(VERST.AOUT)

2 FCOD

(VERST.AOUT)

C0109

−199.99

{0.01 %}

199.99 FCODE (Offset AOUT)

FCODE
(OFFSET)

0.00

FCODE
(OFFSET)

0.00

C0114

0
1

HIGH active
LOW active

DIGIN polarity
Terminal polarity

1 DIGIN1 POL

0

X5/E1

2 DIGIN2 POL

0

X5/E2

3 DIGIN3 POL

0

X5/E3

4 DIGIN4 POL

1

X5/E4

5 DIGIN5 POL

0

X5/E5

C0116

s

® Selection list 2 Signal configuration FD0−xx

Free digital outputs can only be evaluated
when networked with automation interfaces.

1 FDO−O0

1000 FIXED0

... ...

...

...

32 FDO −31

1000 FIXED0

C0117

s

®

® Selection list 2 DIGOUTx

Signal configuration

à

Depending on C0005

1 DIGOUT1

15000 DCTRL−TRIP

X5/A1

2 DIGOUT2

10650 CMP1−OUT

X5/A2

3 DIGOUT3

500

DCTRL−RDY

X5/A3

4 DIGOUT4

5003 MCTRL−MMAX

X5/A4

C0118

0
1

HIGH active
LOW active

DIGOUTx
Terminal polarity

1 DIGOUT1 POL

1

X5/A1

2 DIGOUT2 POL

1

X5/A2

3 DIGOUT3 POL

0

X5/A3

4 DIGOUT4 POL

0

X5/A4

C0120 OC6 LIMIT

0

0

{1 %}

120 Threshold for I

2

× t monitoring (motor).

l

0 = I

2

× t monitoring switched off

l

I

2

× t > C0120

ð Trip OC6

C0121 OH7 LIMIT

150

45

{1 °C}

150 Temperature for OH7

Threshold for motor temperature warning

C0122 OH4 LIMIT

85

45

{1 °C}

85 Temperature for OH4

Threshold for heatsink temperature warning

C0125 BAUDRATE

0

0
1
2
3
4

9600 baud
4800 baud
2400 baud
1200 baud
19200 baud

LECOM baud rate
LECOM baud rate for 2102 module