Configuration, Code table – Lenze EVS9332xK User Manual

Page 355

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−81

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1726

−2147483647

{1 inc}

2147483647 STORE3

Memory

1

0

Memory location 0

2

0

Memory location 1

...

0

...

16

0

Memory location 16

C1727

0

0

{1}

15 STORE3

Initial value at STORE3−SEL−IN

C1735

0

CCTRL2
Source for touch probe catch−up speed in the
event of deviations

0

Code 1365/1

l

Detected deviations are compensate as
fast as possible with the speed selected
under C1365/1.

l

Value under C1365/1 = 0: No
compensation of deviations.

1

Input CCTRL2−TP−SPEED−LIM

l

Detected deviations are compensated
with the speed selected at
CCTRL2−TP−SPEED−LIM.

l

Signal at CCTRL2−TP−SPEED−LIM = 0: No
compensation of deviations.

l

The input is only active if
CCTRL2−TP−SYNC−BUSY = High.

C1740

0

PHINT5
Source for touch probe catch−up speed in the
event of deviations

0

Code 1741/1

l

Detected deviations are compensated
with the speed selected under C1741/1.

l

Value in C1741/1 = 0: no compensation of
deviations.

1

Input PHINT5−TP−SPEED−LIM

l

Detected deviations are compensated
with the speed selected at
PHINT5−TP−SPEED−LIM.

l

Signal at PHINT5−TP−SPEED−LIM = 0: No
compensation of deviations.

l

The input is only active if
PHINT5−TP−SYNC−BUSY = HIGH.

C1741

0.0000

{0.0001

rpm}

15000.0000 PHINT5

Maximum touch probe catch−up speed

1

10.00

00

C1799

1250 20

{1}

1250 DFOUT f

max

(kHz)

1250 corresponds to 500 kHz

C1810

g

SW identification LECOM

C1811

g

SW creation

Advertising