Commissioning

Important notes

6

6.1

l

6.1−1

EDSVS9332K EN 8.0−07/2013

6.1

Important notes

(

Stop!

For applications with active loads (e.g. hoists), you must set
C0172 = 0 (OV reduce: threshold for activation of brake torque
reduction before OV message) so that an overvoltage message
(OV) can be generated.

ƒ

As long as the overvoltage message (OV) is active, pulse inhibit
is set and the drive operates in zero−torque mode.

ƒ

The controller inhibit is also evaluated by the holding brake
(BRK)" function block.

Use a PC with the »Global Drive Control« (GDC) PC software for
commissioning. The full functionality of the servo cam profiler can only be
obtained through GDC

.

ƒ Which GDC version is required?

9300 servo cam profiler

»Global Drive Control«

Software version

Version

3.3

3.6 or higher

3.4

4.4 or higher

4.0

4.4 or higher

ƒ Possible communication paths between GDC and controller including

adapters and connection cables required:

Controller

Connection

PC

Interface

PC adapter

Interface

Integrated system
bus or
CANopen
communication
module
EMF2175IB

System bus cable
(supplied with the
system bus
adapters)

System bus adapter
EMF2173IB

Parallel (printer
interface)

System bus adapter
EMF2177IB

USB

Communication
module LECOM−A/B
EMF2102IBCV001

Serial cable
EWL0020
EWL0021

A standard RS232 / RS485
converter and an RS485
connection cable are required
for LECOM−B.

Serial (RS232)

Communication
module LECOM−LI
EMF2102IBCV003

Optical fibre
EWZ0006
EWZ0007

Optical fibre adapter
EMF2125IB
EMF2126IB

Active loads

»Global Drive Control« (GDC)

Advertising
This manual is related to the following products: