Configuration, Code table – Lenze EVS9332xK User Manual

Page 306

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−32

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0739 KANALANZAHL

4

1

{1}

4 OSZ

Number of channels to be measured

C0740 DATA READ

0

OSZ

1

0

0

{1}

65535 Selection of the starting point for reading out

the data memory. Allows selective access to a
memory block

2

0

0
1

Data reading inhibited
Data reading enabled

Inhibit "Read memory"

C0741

OSZ

1 VERSION OSZ

g

Version

2 LENGTH

MEMORY

Memory size

3 DATA WIDTH

Data width

4 NO. CHANNELS

Number of channels

C0742 LENGTH OF DB

g

OSZ
Display of data block length

C0743 READ DB

g

OSZ
Reading of an 8−byte data block

C0744 MEM: DEPTH

2048 0

1
2
3
4
5
6

512 measured values
1024 measured values
1536 measured values
2048 measured values
3072 measured values
4096 measured values
8192 measured values

OSZ
Adaptation of the memory size to the
measurement task

C0749

g

OSZ
Information on measured value storage

1 BRK:OFF INDEX

2 TRIGGER INDEX

3 END INDEX

C0750 VP DENOM

16

1
2
4
8
16
34
64
128
256
512
1024
2048
4096
8192
16384

Vp = 1
Vp = 1/2
Vp = 1/4
Vp = 1/8
Vp = 1/16
Vp = 1/32
Vp = 1/64
Vp = 1/128
Vp = 1/256
Vp = 1/512
Vp = 1/1024
Vp = 1/2048
Vp = 1/4096
Vp = 1/8192
Vp = 1/16384

DFRFG1
Denominator of the position controller gain

C0751 DFRFG1 TIR

1.000 0.001

{0.001 s}

999.900 DFRFG1

T

ir

(acceleration time)

C0752 MAX SPEED

3000 1

{1 rpm}

16000 DFRFG1

Maximum speed (here: maximum catch−up
speed)

C0753 DFRFG1 QSP

0.000 0.000

{0.001 s}

999.900 DFRFG1

Deceleration time T

if

when deceleration ramp

is activated

C0754 PH ERROR

2

.

10

9

10

{1 inc}

2

.

10

9

DFRFG1
Following error

C0755 SYN WINDOW

100

0

{1 inc}

65535 DFRFG1

Synchronisation window

Advertising
This manual is related to the following products: