Configuration

Monitoring functions

8

8.3

l

8.32

EDSVS9332K

EN 8.0−07/2013

Possible fault responses

l Lenze setting

ü Can be set

Monitoring

Off

Fail−QSP

Warning

Message

TRIP

Code

Source

Description

Fault message

0015

OC5

Device utilisation I x t (fix 100%)

MCTRL

l

0016

OC6

I

2

x t overload

MCTRL

l

0018

OC8

I

2

x t overload advance warning

MCTRL

C0606

ü

l

ü

x032

LP1

Failure of a motor phase
(current limit adjustable under C0599)
Caution: Can only be used with asynchronous motors. The
function block MLP1 must be entered in C0465.

MCTRL

C0597

ь

ь

l

x082

Sd2

Resolver error at X7
Note: If monitoring is switched off or in the case of "Warning",
the machine can reach very high speeds in the case of fault,
which may result in the damage of the motor and the machine
that is driven!

MCTRL

C0586

l

ь

ь

x083

Sd3

Interruption of the digital frequency coupling. The input signal
˜Lamp Control˜ at X9/8 is LOW
Please note: In the case of "Warning" (C0587 = 2), the drive can
be destroyed if the fault is not eliminated in time!

MCTRL

C0587

l

ь

ь

x085

Sd5

At analog input X6/1, X6/2, the input current is < 2 mA
Monitoring only possible if C0034 = 1

MCTRL

C0598

ь

ь

l

x087

Sd7

Absolute value encoder error at X8

MCTRL

ü

l

x088

Sd8

SinCos encoder error at X8
(filter setting under C0575)

MCTRL

C0580

ü

l

Speed

x190

nErr

Speed control error
(speed window adjustable under C0576)

MCTRL

C0579

ь

ь

ь

l

x200

NMAX

Maximum speed (C0596) has been exceeded.

MCTRL

l

Time−out / overflow

0105

H05

Internal fault (memory)

Internal

l

x153

P03

Following error (digital frequency > C0255)

Internal

C0589

ü

l

ü

x163

P13

Angle controller overflow

Internal

C0590

l

ь

ь

x169

P19

Input signal at X9 is limited

Internal

C1292

ü

l

ü

Parameter setting

0072

PR1

Check sum error in parameter set 1

Internal

l

0074

PEr

Program error

Internal

l

0075

PR0

Error in the parameter sets

Internal

l

0079

PI

Error during parameter initialisation

Internal

l

x089

PL

Error during rotor position adjustment

Internal

l

Explanation of the error numbers: