Dc−bus operation – Lenze EVS9332xK User Manual

Page 418

Advertising
background image

DC−bus operation

Fuses and cable cross−sections

10

10.3

l

10.3−2

EDSVS9332K EN 8.0−07/2013

Inverter

DC fuse 14 × 51

(EFSGR0xx0AYHx)

DC fuse 22 × 58

(EFSGR0xx0AYIx)

Installation in

accordance with

EN 60204−1

Type

Mains

Rated current of fuse

Rated current of fuse

+U

G

, −U

G

Laying system

B2

C

[A]

[A]

[mm

2

]

[mm

2

]

EVS9321

3/PE

400 V

12

12

1.5

1.5

EVS9322

12

12

1.5

1.5

EVS9323

12

12

1.5

1.5

EVS9324

20

20

1.5

1.5

EVS9325

40

40

4.0

4.0

EVS9326

50

50

6.0

1)

4.0

1)

Pin−end connector required, since a maximum cable cross−section of 4 mm

2

can be connected to

the inverter.

Inverter

DC fuse NH1

(EFSGRxxx0ANVx)

DC fuse 22 × 58

(EFSGR0xx0AYIx)

Installation in

accordance with

EN 60204−1

Type

Mains

Rated current of fuse

Rated current of fuse

+U

G

, −U

G

Laying system

B2

C

[A]

[A]

[mm

2

]

[mm

2

]

EVS9327

3/PE

400 V

100

100

25

EVS9328

100

100

25

EVS9329

200

25

EVS9330

200

50

EVS9331

200

50

Inverter

DC fuse NH2

(EFSGRxxx0ANWx)

DC fuse 22 × 58

(EFSGR0xx0AYIx)

Installation in

accordance with

EN 60204−1

Type

Mains

Rated current of fuse

Rated current of fuse

+U

G

, −U

G

Laying system

B2

C

[A]

[A]

[mm

2

]

[mm

2

]

EVS9332

3/PE

400 V

250

95