Wiring of the standard device – Lenze EVS9332xK User Manual

Page 117

Advertising
background image

Wiring of the standard device

Standard devices in the power range 15 ... 30 kW

Motor connection

5

5.5

5.5.6

l

5.5−9

EDSVS9332K EN 8.0−07/2013

PE

PE

T1

T1

T2

T2

U

V

W

4

4

T1
T2

2.5 Nm
22,1 lb-in

T1
T2

2.5 Nm
22,1 lb-in

}

+

PE

}

+

PE

0

0

1

1

3

2

2



‚

U, V, W,
PE

5 Nm
44 lb-in

M 6

9300std030

Fig. 5.5−5

Motor connection with PTC thermistor or thermal contact (NC contact)

 0 Motor connection with Lenze system cable with integrated control

cable for the motor temperature monitoring

1 Shield sheet

Clamp entire shield and shield of the control cable for the motor
temperature monitoring with the straps. If required, fix by means of
cable tie.

‚ 0 Motor cable connection and separate control cable for the motor

temperature monitoring

1 Shield sheet

Clamp shield of the motor cable and shield of the cable for the motor
temperature monitoring with the straps. If required, fix by means of
cable tie.

2 PE stud

PE cable connection with ring cable lug

3 U, V, W

Motor cable connection
Check the correct polarity. Observe maximum length of the motor cable.
Max. connectable cable cross−section: 50 mm

2

with ring cable lug

4 T1, T2 for motor temperature monitoring

Cable connection for PTC thermistors or thermal contacts (NC contacts)