Configuration – Lenze EVS9332xK User Manual

Page 303

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−29

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0675

s

LOAD

1000 FIXED0

® Selection list 2 RFG1

Configuration of digital input signal

C0676

g −199.99

{0.01 %}

199.99 RFG1

Display of analog input signals

1 (C0673)

2 (C0674)

C0677 (C0675)

g

RFG1
Display of digital input signal

C0680 FUNCTION

6

1
2
3
4
5
6

IN1 = IN 2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|

CMP1
Selection of the function for comparing
inputs IN1 and IN2

C0681 HYSTERESIS

1.00

0.00

{0.01 %}

100.00 CMP1

Hysteresis

C0682 WINDOW

1.00

0.00

{0.01 %}

100.00 CMP1

Window

C0683

s

® Selection list 1 CMP1

Configuration of analog input signals

1 CMP1−IN1

5001 MCTRL−NACT

2 CMP1−IN2

19500 FCODE−17

C0684

g −199.99

{0.01 %}

199.99 CMP1

Display of analog input signals

1 (C0683/1)

2 (C0683/1)

C0685 FUNCTION

1

1
2
3
4
5
6

IN1 = IN2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|

CMP2
Selection of the function for comparing
inputs IN1 and IN2

C0686 HYSTERESIS

1.00

0.00

{0.01 %}

100.00 CMP2

Hysteresis

C0687 WINDOW

1.00

0.00

{0.01 %}

100.00 CMP2

Window

C0688

s

® Selection list 1 CMP2

Configuration of analog input signals

1 CMP2−IN1

1000 FIXED0%

2 CMP2−IN2

1000 FIXED0%

C0689

g −199.99

{0.01 %}

199.99 CMP2

Display of analog input signals

1 (C0688/1)

2 (C0688/2)

C0690 FUNCTION

1

1
2
3
4
5
6

IN1 = IN 2
IN 1 > IN2
IN 1 < IN2
|IN1| = |IN2|
|IN1| > |IN2|
|IN1| < |IN2|

CMP3
Selection of the function for comparing
inputs IN1 and IN2

C0691 HYSTERESIS

1.00

0.00

{0.01 %}

100.00 CMP3

Hysteresis

C0692 WINDOW

1.00

0.00

{0.01 %}

100.00 CMP3

Window

Advertising
This manual is related to the following products: