Configuration

Code table

8

8.4

l

8.4−11

EDSVS9332K EN 8.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0173

s

UG LIMIT

1

Adaptation of DC−bus voltage thresholds
Check during commissioning and adapt if
necessary!
All interconnected drive components must
have the same thresholds!

0

Mains<400V +−brake LU=285V,
OU=770V−755V

Operation on mains <400 V with or without
brake unit

1

Mains=400V +−brake LU=285V,
OU=770V−755V

Operation on 400 V mains with or without
brake unit

2

Mains=460V +−brake LU=328V,
OU=770V−755V

Operation on 460 V mains with or without
brake unit

3

Mains=480V −brake LU=342V,
OU=770V−755V

Operation on 480 V mains without brake unit

4

Mains=480V +brake LU=342V,
OU=800V−785V

Operation on 480 V mains with brake unit

C0178 OP TIMER

g 0

{1 s}

4294967295 Elapsed−hour meter

l

Time when the controller was enabled

C0179 MAINS TIMER

g 0

{1 s}

4294967295 Power−on time meter

l

Time when the mains was switched on

C0182 TI S−SHAPED

20.00 0.01

{0.01 s}

50.00 NSET

T

i

time of the S−shaped ramp function

generator
(determines the shape of the S profile)

l

Small values

Þsmall S rounding

l

Large values

Þlarge S rounding