Commissioning

Transfer of motion profiles

Transfer of profile data from the PLC/IPC to the controller

6

6.11

6.11.4

l

6.11−7

EDSVS9332K EN 8.0−07/2013

Y

X

Y1

Y2

Y3

Y4

Y5

Y6

Y7

Y8

Y9

Y10

Y11

X1

X2

X3

X4

X5

X6

X7

X8

X9

X10

X11

X

X1
X2
X3



X11

Y

Y1
Y2
Y3



Y11

9300kur060

Fig. 6.11−5

Example of a profile with absolute data model (assignment of the X/Y value pairs)

3. Reading or writing of X data:

– Writing as increments with C0504/3 or reading as increments with

C0504/5.

– Writing as units with C0511/1 or reading as units with C0511/2.

4. Enter the first interpolation point to be specified in Y direction

(C0505/4)
– Constant overwriting of code C0505/3 or C0505/4 with the

corresponding point number {(0 ... n−1) for n points} means that every
point of the profile can be addressed separately.

5. Reading or writing of Y data:

– Writing as increments [inc] with C0504/4 or reading as increments

with C0504/6.

– Writing as user units [units] with C0512/1 or reading as user units

with C0512/2.

)

Note!

Wait for ACK" from the system before you write the next X
value.
The next higher interpolation point is automatically addressed
after a writing or reading process (auto increments).
You can either write all X values and then all Y values or write
one each. Condition:

ƒ

X0 must always be zero. All other values will be rejected.

ƒ

Y0 is the starting point of the profile.