Code−oriented transfer mode
13.1
l
13.1−8
EDSVS9332K EN 8.0−07/2013
C1305/1
C1305/2
C1306
9300kur020
Fig. 13.1−8
Entry of the Y coordinates in the "Basic settings" dialog box of GDC
YPOS [inc]
+ YPOS [s_units] @
65536 [inc
ńrpm] @ C1305ń1
C1306 [s_units
ńrpm] @ C1305ń2
YPOS = position target
YPOS
Target position
C1305/1
Gearbox numerator
C1305/2
Gearbox denominator
C1306
Feed constant
ƒ Enter all values in [inc].
ƒ Y values can be entered freely within the permissible value range.
ƒ Permissible value range: +2
31
to −2
31
Y
X
Y1
Y2
Y3
Y4
Y5
Y6
Y6
Y7
Y8
Y9
Y10
Y11
X1
X2
X3
X4
X5
X7
X8
X9
X10
X11
X6
0
1
9300kur066
Fig. 13.1−9
Change of a Y coordinate
Y coordinates (cam drive)